PAC 1200 Miele AirControl
Air purifier
for reducing air impurities and aerosols in rooms up to 200 m².
- Maximum air throughput up to 3.000m3/hNote
Calculation of the required air filtration capacity in m³/h for the room air to be replaced six times per hour:
Room width x room length x room height x 6 - Optimum safety thanks to five-stage filter system incl. HEPA H14Five-stage filter system
The filter removes at least 99.995 % of all suspended matter, viruses, bacteria and mould fungi. - Miele ThermoControl – thermal inactivation of relevant pathogensMiele ThermoControl
The air is heated to 70 °C upstream of the filter cartridge to inactivate relevant pathogens. - Ventilation requirement indicated by integrated CO2 sensorIntegrated CO2 sensor
In CO2 mode, air throughput adjusts to the quality of room air for quieter operation . - Automatic programmes, e.g. for presetting the operating times
- You can find out more about the AirControl air purifier here
Product benefits

Filtration of pollen and allergens
Allergens reduced considerably
The multi-stage filter system reliably removes pollen and allergens from the room air.

No tipping
Stable
Greater stability thanks to retractable adjustable feet.
Product details
PAC 1200 Miele AirControl
EAN 4002516497332 / Article number 55120000GB / Material number 11929660
EAN 4002516497332 / Article number 55120000GB / Material number 11929660
Suitable for retirement and care homes | |
---|---|
Suitable for hospitals | |
Suitable for surgeries and dental practices | |
Suitable for laboratories | |
Suitable for small restaurants/bars | |
Suitable for fast-food restaurants | |
Suitable for hotels | |
Suitable for guesthouses | |
Suitable for canteens | |
Suitable for child-care facilities | |
Suitable for universities and schools | |
Suitable for offices | |
Suitable for retail | |
Suitable for small businesses | |
Suitable for sports clubs | |
Suitable for fire brigades and rescue services | |
Suitable for private households |
Min. air throughput in m³/h | 150 |
---|---|
Max. air throughput in m³/h Note Calculation of the required air filtration capacity in m³/h for the room air to be replaced six times per hour: Room width x room length x room height x 6 | 3.000 |
Max. recommended room size in m² Note The maximum recommended room size refers to rooms with a ceiling height of 2.70 m (with the room air volume being replaced six times per hour and HEPA H14 filtration capacity). | 200 |
Five-stage filtration | |
Continuous operation possible |
Filtration of aerosols | |
---|---|
Filtration of relevant pathogens (viruses, bacteria and mould fungi) | |
Filtration of coarse dust and particulates | |
Filtration of (tobacco) smoke | |
Filtration of VOCs | |
Filtration of unpleasant odours | |
Filtration of pollen and allergens |
Control type | Electronic controls |
---|---|
LCD display with date and time | |
Programme selection | Touch controls |
Control indicator for main filter replacement | |
Room temperature indicator | |
CO2 indicator | |
Fan output indicator | |
Choice of display languages |
Electrical connection | 1N AC 230V 50/60HZ |
---|---|
Heater rating in kW | 1,300 |
Total current consumption in A | 8,000 |
Total rated load in kW | 1,850 |
Length of mains connection cable in m Note The length refers to the supply lead on the outside of the machine. | 3,10 |
External dimensions, net height in mm | 1.300 |
---|---|
External dimensions, net width in mm | 700 |
External dimensions, net depth in mm | 700 |
External dimensions, gross height in mm Note Including packaging | 1.310 |
External dimensions, gross width in mm Note Including packaging | 720 |
External dimensions, gross depth in mm Note Including packaging | 740 |
Net weight in kg | 110 |
Gross weight in kg Note Including packaging | 115 |
Maximum floor load in N Maximum floor load The maximum floor load states the maximum weight (N) that can be placed on the supporting surface on which the machine is installed. This value is the result of adding up the machine weight and the dynamic forces that occur during operation. | 257 |
Sound pressure level in accordance with EN ISO 11204 with a fan output of 25 % in dB (A) Note All measurements for the sound pressure level in accordance with EN ISO 11204 are performed at a distance of 100 cm from the machine. | 49 |
---|---|
Sound pressure level in accordance with EN ISO 11204 with a fan output of 50 % in dB (A) Note All measurements for the sound pressure level in accordance with EN ISO 11204 are performed at a distance of 100 cm from the machine. | 59 |
Sound pressure level in accordance with EN ISO 11204 with a fan output of 75 % in dB (A) Note All measurements for the sound pressure level in accordance with EN ISO 11204 are performed at a distance of 100 cm from the machine. | 67 |
Sound pressure level in accordance with EN ISO 11204 with a fan output of 100 % in dB (A) Note All measurements for the sound pressure level in accordance with EN ISO 11204 are performed at a distance of 100 cm from the machine. | 74 |
Heat dissipation into the room in MJ/h Heat dissipation into the room Air purifiers emit heat into the room when in operation. The released amount of heat/time depends on the set output and the intensity of use. The stated maximum value can be used to control the temperature of the area or to calculate an increase in room temperature. | 1,50 |
Maximum housing temperature during filter drying in °C Note The housing temperature of the air purifier can fluctuate during operation. Particularly during thermal inactivation, the housing temperature will increase. However, the surface temperature does not pose a risk. | 58 |
Manual operation | |
---|---|
CO2-controlled automatic mode | |
Time-controlled automatic mode | |
CO2-controlled automatic mode with time control |
Coarse dust pre-filter | |
---|---|
Particulate pre-filter | |
Class H14 HEPA filter | |
HEPA filter filtration efficiency (as per DIN EN 1822) in % | 99,995 Note Every HEPA filter has been tested and boasts a filtration efficiency of 99.995 % for particles from 0.1–0.2 µm. This filtration efficiency refers to the particle size that is most difficult to capture. The filter has an even higher filtration efficiency for bigger and smaller particles. |
HEPA H14 and particulate pre-filter life cycle in h (depending on ambient conditions) | 4.000 |
Active charcoal filter | |
Exhaust filter | |
Miele ThermoControl | |
Ozone-free | |
CO2 sensor | |
270° air intake | |
Optimum air distribution | |
Continuously variable air throughput | |
Ventilation function booster | |
Tamper-proof | |
Robust castors | |
No tipping |
CE | |
---|---|
WEEE | |
Complies with Machinery Directive 2006/42/EC |
Downloads
You can download these CAD data for free. You will receive a download link via e-mail.
ZIP archive in 3D format FBX
ZIP archive in 3D format IFC
ZIP archive in 3D format RFA
ZIP archive in 3D format RVT
ZIP archive in 3D format DWG