DA 3190Enlarge Image


Reserve a place at a Live Cooking Demonstration.

 
DA 3190

Design

Integrated cooker hood
Extraction mode
Recirculation mode possible with optional conversion kit and active charcoal filter

Dimensions

For installation in a minimum of 90cm wide and 46cm high upper cabinet
Pull-out deflector plate, 90 cm wide
The front edge can be concealed by an aluminium or white lightshield (optional accessory) or by a lightshield to match the kitchen furniture (fitting kit required)

Controls

Touch controls with LED lights for ON/OFF, hob lighting and power regulation
Three fan settings plus an Intensive setting
Memory function for fan, lighting and power level (in event of power outage)
Pulling the deflector plate out and pushing it in switches the cooker hood on and off automatically
The intensive setting can be programmed to switch off automatically after 10 minutes

Features

Electronic power regulation
Double acting radial fan
Two removable, dishwasher-safe stainless steel grease filters
Non-return flap
Ducting outlet through top of cooker hood
Recommended ducting diameter: 150 mm
Halogen lighting, 2 x 50 Watt

Extraction rate

Extraction 150 mm Ø nach EN 61591
Int. 550 m³/h, 64 dB(A) re 1 pW (52 dB(A) re 20 µPa Sound pressure)
Max. 400 m³/h, 56 dB(A) re 1 pW (44 dB(A) re 20 µPa Sound Pressure)
Extraction 125 mm Ø nach EN 61591
Int. 520 m³/h, 65 dB(A) re 1 pW (53 dB(A) re 20 µPa Sound Pressure)
Max. 380 m³/h, 57 dB(A) re 1 pW (45 dB(A) re 20 µPa Sound Pressure)
Recirculation 150 mm Ø nach EN 61591
Int. 350 m³/h, 72 dB(A) re 1 pW (60 dB(A) re 20 µPa Sound Pressure)
Max. 280 m³/h, 67 dB(A) re 1 pW (54 dB(A) re 20 µPa Sound Pressure)

Safety

Switches off automatically after 10 hours

Standard accessories

Reducing stub for 125 mm Ø

Optional accessories

Active charcoal filter DKF 13-1
Recirculation conversion kit DUU 150
Lightshield (aluminium or white)
Fitting kit for lightshield DML 300
Wall pipe MR 100-150
Flexible ducting DAS 100-150
Condensate trap DKS 125/150

Product information may be subject to change.

Installation drawings

1. The front section of the wall housing unit must be fitted with a
shelf to the depth of the partition
wall.
2. The partition wall must be removable.
3. Extraction mode; measurements of height and cut outs of installed
accessories must be considered (e.g. silencer,
DSM-Module)
4. Recirculation with conversion kit DUU 151
5. Accessory DSM 400
* Can also be fitted in a 550 mm wide wall unit